Lisun Electronics (Shanghai) Co., Ltd.
Main products:Goniophotometer,Intergrating Sphere,Colorimeter,Photometer,EMI Receiver
Products
Contact Us
  • Contact Person : Mr. Jiang Jacky
  • Company Name : Lisun Electronics (Shanghai) Co., Ltd.
  • Tel : 86-021-51083341
  • Fax : 86-021-51083342
  • Address : Shanghai,Shanghai,Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District, Shanghai, China
  • Country/Region : China
  • Zip : 201803

Ring Wave Generator - RWG61000-12

Ring Wave Generator - RWG61000-12
Product Detailed
Ring Wave Generator - RWG61000-12 1.conformity to IEC standard IEC 61000-4-12 and ANSI-C62-41 2.high accuracy, easy operation

RWG61000-12 Ring Wave Generator is the test equipment in conformity to IEC (the International Electrotechnical Commission) standard IEC 61000-4-12 and ANSI-C62-41. This instrument is used for the simulative electrical network, the power supply of the reactive load and the control line switch, as well as sensing the ring wave of the low voltage cables terminal equipment caused by the disconnection of the power circuit, fault and insulation breakdown or lightning stroke.Ring Wave Generator - RWG61000-12 Specifications:1.Main technical parameters•  Voltage rising time (the first peak): 0.5μs±20% (open circuit state)•  Current rising time (the first peak): ≤1μs(short circuit state)•  Oscillation frequency: 100kHz±10% •  Attenuation (for each peak): the second peak value is 40%~80% of the first peak value, the third peak value is 40%~80% of the second peak value,the forth peak value is 40%~80% of the third peak value, the most ideal attenuation ratio is that the next peak value is 60% of the prior peak value•  Recurrence:1~60 transient states per minute•  Output impedance: 12Ω and 50Ω±20% (switchable)•  Open circuit peak voltage: 0.20kV(-10%)~6.0kV(+10%)•  Short circuit current (minimum peak):When the output impedance is 12Ω, the short circuit current is 500A; when the output impedance is 50Ω, the short circuit current is 120A•  The phase relation with the supply frequency: (0°~360°,10°stepping)•  The polarity of the first semi-circle: positive or negative can switch over•  Pulse frequency:1~999 times•  RWG61000-12 has already combined with a coupling/decoupling network which is 3-phases/5-wires and output 380V/16A max for EUT2.Output voltage waveform definitionOscillation frequency of the open-circuit voltage (1/T):100KHz±10% Applicable standards: IEC61000-4-12:2006 Open-circuit output voltage(PK1): (200V~4000V)±10% Open-circuit voltage waveform frontier(T1): 0.5μs±20% at (10%~90%)PK1Open-circuit voltage wave attenuation rate: 0.4<(PK2)/(PK1)<0.80.4<(PK3)/(PK2)<0.80.4<(PK4)/(PK3)<0.83.Short-circuit current wave frontier(T2): 10%~90% P1≤1μs 

Oscillation frequency of short-circuit current (1/Ts):100KHz±10%Applicable standard: IEC61000-4-12:2006I=U/R The short-circuit current is codetermined by the selective high pressure and internal resistance (12Ω and 50Ω±20%), the current value should meet ohm’s law I=U/R.Short-circuit current wave attenuation rate: 0.4<(P2)/(P1)<0.80.4<(P3)/(P2)<0.80.4<(P4)/(P3)<0.8

3.Short-circuit current wave frontier(T2): 10%~90% P1≤1μs 

Oscillation frequency of short-circuit current (1/Ts):100KHz±10%Applicable standard: IEC61000-4-12:2006I=U/R The short-circuit current is codetermined by the selective high pressure and internal resistance (12Ω and 30Ω±20%), the current value should meet ohm’s law I=U/R.Short-circuit current wave attenuation rate: 0.4<(P2)/(P1)<0.80.4<(P3)/(P2)<0.80.4<(P4)/(P3)<0.8   

Products of this category:

ESD61000-2: ESD Simulator (electrostatic gun) is in full compliance with IEC61000-4-2,  EN61000-4-2 and GB/T17626.2 standards.KH3961: EMC testing is a science subject which studies how electric appliance or system can work together without causing performance disability within limited space, limited time, limited frequency spectrum resource. This EMI testing system measures PD,QP and AV range from: 20dBμV-130dBμV(9kHz-150kHz);10dBμV-90dBμV (150kHz-30MHz).KH3962: This EMI Receiver system measure range is from 9kHZ~300mHZ.EFT61000-4: This EFT immunity measurement meets the standard requirement of IEC 61000-4-4, EN61000-4-4 and GB/T17626.4 (high voltage regulator is adopted, and displayed by LCD).SG61000-5: The performance of this surge generator meets the IEC61000-4-5, EN61000-4-5 and GB/T17626.5 standards.RWG61000-12 Ring Wave Generator is the test equipment in conformity to IEC standard IEC 61000-4-12 and ANSI-C62-41. CSS61000-11: Voltage dip and interruption generator meets the standard requirements of IEC 61000-4-11, EN61000-4-11 and GB/T17626.11.EMC200A/EMC200B: EMI Receiver equipped with this artificial network can test interference voltage of mains terminals.CDN-M23: EMI Receiver equipped with this coupling decoupling network is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30~300MHz.AB-CLP: EMI Receiver equipped with this absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.VOL-PBE: EMI Receiver equipped with this voltage probe can test disturbance voltage from load terminals or control terminals.

Ring Wave Generator - RWG61000-12

Other products


Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.